Accu chek active meter manual




















Chapter 6: Technical Information Product Limitations Product Safety Information Money-Back Guarantee Additional Supplies Information for Professional Caregivers Shows blood sugar results, messages, and results stored in memory. Press this button to enter the Set mode, move between fields such as time, date, etc. Insert test strip here. Use your thumb to slide the battery tray up and out of the meter.

Remove the plastic strip and throw it away. Slide the battery tray back into the meter until it locks into place. Always keep an extra battery on hand. When this happens, test results are still saved in memory. The hour will flash. Press to. You may hold the button down to scroll forward quickly. With the meter off, slide the orange code key into the code key slot. It should easily snap into place. Throw away the old code key.

Be sure the code key matches the code on the test strip container. Welcome to ManualMachine. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions.

Enter a new password. Why Regular Blood Sugar Testing Is Important Checking your blood sugar can make a big difference in how well you manage your diabetes on a daily basis. Need Help? Display — Shows blood sugar results, messages, and results stored in memory. M Button — Press this button to enter or exit the Memory mode or change values in the Set mode. If you perform a blood glucose test up to 1 hour before a test reminder, the meter cancels the test reminder.

Page 28 Testing blood glucose Checking your test results The test strip itself allows you to estimate the test result through colour comparison and thus also to check the displayed result. Page 29 Testing blood glucose Symbols before, during or after a blood glucose test The following symbols can appear on the display before, during or after a test.

Symbol Meaning The battery is almost empty. Page 30 Testing blood glucose Evaluating test results Blood glucose results are influenced, amongst others, by nutritional choices, medicine taken, state of health, stress and physical activity.

Page 31 Testing blood glucose Did you bend the test strip while sliding it into the meter? Did you apply the blood drop immediately after it formed? Did you bend or move the test strip before or during the test?

Page Using The Meter As A Diary Using the meter as a diary Using the meter as a diary The meter can save up to test results with the time and the date and calculate averages from the saved test results. The meter automatically saves all test results.

If all the memory locations are occupied, the oldest test result is deleted to create space for the new one when you perform a new blood glucose test.

Page Retrieving Averages Using the meter as a diary Retrieving averages The averages calculated by the meter are calculated for 3 groups of test results and for 4 time periods per group.

The meter calculates the averages in the following order: Group Test results Period days All test results Only test results which have been marked with Page 36 Using the meter as a diary Back Turn off No average To go back to the saved test To turn the meter off: If there are no test results saved results: for the selected average, three Press the M button and S button dashes are displayed.

Roche Diagnostics offers a variety of special diabetes management hardware and software products which enhance the integrated diary functions of your meter. Page 38 Analysing test results on the PC If the meter is off, it is turned on when it gets connected to the Once the connection to the computer. There you will find all all saved test results.

Nonetheless, there must be a battery in the meter. To turn the meter off, unplug the For approximately 3 seconds, USB connector from the meter is displayed. The flashing displayed on the display and the angle. Page 44 Checking your meter Sources of inaccurate control tests If the result of the control test is outside the specified concentration range, repeat the control test.

If the result of the second test is also outside the concentration range, check the following points. If your responses to the questions below are different from those given, make the respective corrections when you perform the next test.

Page 45 Checking your meter Are the test strip guide and measurement window clean? Has the control solution been open for less than 3 months? Once opened, control solutions keep for only 3 months. They must not be used after this period. Page Cleaning The Meter Cleaning the meter Cleaning the meter If the meter is dirty, it may be necessary to clean it.

The cover window and its surrounding area centred onto the meter. Page Changing The Battery Changing the battery Changing the battery When the battery symbol appears on the display for the first time, the battery is almost empty. You can perform approximately 50 more tests with the battery. Change the battery as soon as possible. The battery has already lost a lot of power and changeable conditions e. Page 49 Changing the battery Never throw batteries into a fire.

They may explode. CLICK Dispose of used batteries in an environmentally friendly way at a collection depot or through your dealer. Place the battery compartment Press the battery compartment cover back on again. Other test strips Read this User's Manual carefully and completely before testing blood glucose for the first time.

If you The Accu-Chek Active blood glucose. All rights reserved. Advanced Owner's Booklet, and Package Inserts for the test strips and control solutions.



0コメント

  • 1000 / 1000